Smoke alarms and safety switches: the quiet essentials

Two small devices do more to keep a household alive than most of what a renovation budget is spent on. The code says where the first must go. The second still depends on someone pressing a button.

A ceiling smoke alarm above a switchboard fitted with safety switches
An alarm on the ceiling, a row of safety switches in the board. Both need testing to be worth having. Drawing: Weatherboard Journal.

A fire at night is dangerous chiefly because smoke reaches people who are asleep. An electrical fault is dangerous at any hour, through an appliance, a damaged lead or a wet hand on a tap. Neither hazard gives much warning, and the two devices designed to give it are both small, cheap and easy to forget. One sits on the ceiling. The other lives in the switchboard behind a door most people open once a year.

Smoke alarms: what the code requires

For new houses and for building work that triggers the requirement, the rules are in Part 9.5 of the National Construction Code's Housing Provisions. They are short.

Where. In a Class 1a building, the code's term for an ordinary house, smoke alarms must be located in any storey containing bedrooms, in every corridor or hallway associated with a bedroom. If there is no corridor or hallway, the alarm goes in an area between the bedrooms and the remainder of the building. An alarm is also required in each other storey that does not contain bedrooms. All must be on or near the ceiling.

What kind. Alarms must comply with the Australian Standard AS 3786.

How powered. They must be powered from the consumer mains where mains power is supplied to the building. A battery-only alarm stuck to the ceiling does not meet the standard for new work.

Interconnected. Where there is more than one alarm, they must be interconnected, so that when one sounds they all do. The code's explanatory note adds that this applies within a single dwelling; alarms in one house need not be linked to those next door.

The hallway rule reflects how people are actually caught. A fire that starts in the kitchen or lounge sends smoke along the passage toward the bedrooms, and an alarm in that passage sounds before the smoke reaches the sleepers. Interconnection covers the opposite case: a fire downstairs at the far end of a two-storey house, where a lone alarm would sound out of earshot.

The code makes one concession to nuisance alarms. In a private garage, where exhaust fumes are likely to set off a smoke alarm falsely, another suitable type of alarm may be installed, provided smoke alarms to AS 3786 are installed elsewhere in the house.

Existing houses: check your state

The national code sets the standard for new building work. What an existing house must have, and what a landlord or a seller must provide, is set by each state and territory under its own fire safety or tenancy laws, and those laws can ask for more than the national code does. They also change, and the fire service in your state publishes the current version. If you are selling, leasing or renovating, read it before the electrician arrives.

Whatever the law requires where you live, the code's layout is a sensible minimum for any house: an alarm in every hallway that serves a bedroom, one on every level, all wired in and all linked.

Hard-wired alarms are electrical work. They are connected to the mains, and installing or replacing one is a job for a licensed electrician in every state and territory. Queensland's Electrical Safety Office defines electrical work, under section 18 of the Electrical Safety Act 2002, to include installing, testing, maintaining, repairing, altering, removing or replacing electrical equipment, and its guidance to householders is never to do their own.

Safety switches: what they do

A safety switch, known in the trade as a residual current device, monitors the electricity flowing through a circuit. The Electrical Safety Office describes the function: safety switches continuously monitor the flow of electricity and turn off the power instantly when they detect an unsafe situation. The unsafe situation is current leaking to earth, which is what happens when it passes through a person.

It is easy to confuse a safety switch with the other devices in the board. Circuit breakers and fuses protect the wiring from overload and short circuit. They do not protect people from electric shock, because the current that can stop a heart is far too small to trip them. The Queensland regulator makes the point in a line from its own public campaign: switchboards have lots of circuit breakers, "but it's safety switches that save lives".

The second message of that campaign is its title: one safety switch may not be enough. A safety switch protects only the circuit it is fitted to. Many houses have a single one on the power point circuits and nothing on the lights, the oven, the hot water or the air conditioner. The Office's advice, whether you own or rent, is to consider having safety switches installed on all circuits, and to call an electrician to see whether your home is covered.

To check your own board, open it and look for switches with a test button, usually marked T or "test". Count them, then count the circuits. Any circuit without a test-button device beside or upstream of it is unprotected against shock.

Testing, which nobody does

A safety switch is a mechanical device that can stick. The Electrical Safety Office says they should be tested every three months, and its instructions begin with a courtesy: tell everyone in the house that the power is about to go off. Press the test button. The switch should trip immediately and cut power to its circuits. Reset it. If pressing the button does nothing, the device has failed and an electrician needs to replace it.

Smoke alarms have a test button too, and a manufacture date on the base. Press the button on one and, in an interconnected system, every alarm in the house should sound. Walk to the furthest bedroom with the door shut and check you can hear it.

A workable routine is to tie both tests to something that already happens four times a year, such as the electricity bill or the change of season. Write the date inside the switchboard door.

When you renovate

Building work is the moment these systems are cheapest to bring up to date, because the electrician is on site and the ceilings are open.

  • Ask for alarms to the Part 9.5 layout as a line item in the electrical quote, hard-wired and interconnected.
  • Ask for a safety switch on every final circuit and have it written into the scope.
  • If the switchboard is an old one with rewirable fuses, ask what an upgrade would cost while the electrician is there. If the house predates 1990, say so, because the federal asbestos agency notes that tradespeople may ask where asbestos is before they drill.
  • Get the certificate. Electrical work ends with a compliance document, whose name varies by state: in Victoria it is a Certificate of Electrical Safety, issued for work by a registered electrical contractor or licensed electrician. Keep it with the house papers.

Questions readers ask

For new building work the code requires alarms to be powered from the consumer mains where mains power is supplied. Whether a battery alarm satisfies the law in an existing house depends on your state or territory's rules, which you should check with the local fire service.

My power points have a safety switch. Am I covered?

Only on those circuits. Queensland's Electrical Safety Office warns that one safety switch may not be enough, because each protects only the circuit it is fitted to. Lights, ovens, hot water systems and air conditioners are often on separate, unprotected circuits.