Wind

Cyclone ratings: how a house is held down

Every new house in Australia is given a wind classification before a nail goes in. Get the letter and the number wrong and the engineering that follows is precise, certified and inadequate.

The tie-down chain from roof to footing that holds a house together in high wind
Roof to wall, wall to floor, floor to footing. The chain is only as good as its weakest connector. Drawing: Weatherboard Journal.

Roofs do not blow off houses so much as get sucked off them. Wind accelerating over a roof behaves the way air does over a wing, and in a severe storm the pull upward on a light steel roof can be greater than the weight holding it down. If a window breaks or a garage door buckles on the windward side, the house inflates as well, and the push from inside adds to the pull from outside. What keeps the roof on at that point is a few dozen metal straps and bolts that nobody has looked at since the frame inspection.

The building code's own explanatory text describes the intent for cyclonic areas as making sure the structure can transfer wind forces to the ground with an adequate safety margin, to prevent the building collapsing or being "lifted, or slid off its foundations". It then lists what that takes: an anchorage system in which the roof is connected through the walls to the footings by a chain of connections, a bracing system to stop the building racking sideways, and continuity, so that each structural element is locked to its neighbour throughout.

Reading the classification

For ordinary houses the classification comes from AS 4055, the wind loads for housing standard. It produces a short code. The letter says whether the site is treated as non-cyclonic, N, or cyclonic, C. The number says how severe the design wind is within that family: N1, N2, N3 and upward in most of the country, C1, C2, C3 and upward across the cyclone belt.

Western Australia's building regulator sets out the method in an industry bulletin. The first input is the wind region, read from a map in the standard. The others are local: the terrain category, meaning how rough the surrounding ground is; the topography, meaning whether the house sits on a hill or escarpment; and shielding, meaning whether neighbouring buildings break the wind. Two houses in the same suburb can come out a full classification apart because one backs onto a golf course.

That gap between classes is larger than the labels suggest. The bulletin notes that the net uplift at the top of the walls "can almost double between subsequent wind classifications" for a house with a metal roof, and can rise by more than that under tiles. Tie-down requirements go up in step. A house designed one class too low is not slightly under strength. Its roof connections may be carrying half the load they should be designed for.

Where the ratings go wrong

Building and Energy published that bulletin because its auditors kept finding incorrect classifications on house plans. The errors it lists are instructive for anyone commissioning a new build or a second storey.

  • Using the simple standard on a house it does not cover. AS 4055 is a simplified method for one or two storey housing within set geometric limits. The bulletin quotes them: external wall height under the eaves of no more than 6 m, roof height above natural ground of no more than 8.5 m, width across the ridge line of no more than 16 m, and roof pitch of no more than 35 degrees. Outside those limits the loads must be worked out by an engineer under AS/NZS 1170.2.
  • Ignoring open ground. A large open space within 500 m, such as a golf course or a waterway, changes the terrain category.
  • Ignoring the hill. A site raised above its surroundings takes more wind.
  • Claiming shelter that will not exist. Shielding from surrounding houses can only be counted where those houses will actually be built on each side within five years. The first homes in a new estate stand in the open.

The bulletin adds that the timber framing standard, AS 1684, has similar geometric limits. A tall, wide, steep-roofed house is therefore outside the span tables as well as outside the wind standard, which is two reasons to have an engineer on the job.

The cyclone regions

The National Construction Code divides the country into wind regions on a map in Part 2.2 of the Housing Provisions. Broadly, the non-cyclonic regions cover the south and the inland, and the cyclonic regions run around the northern coast from Western Australia across the Top End and down the Queensland coast. The code's design categories distinguish non-cyclonic wind, cyclonic wind, and the most severe case, cyclonic wind in Region D north of the Tropic of Capricorn.

Western Australia goes further than the national text. The code records state variations for wind regions B and D. In Region B, including the B2 area in the current loading standard, WA requires designers to consider peak external pressure together with increased internal pressure and to use a cyclonic C classification instead of a non-cyclonic one. For Region D north of the Tropic, the 2021 edition of the loading standard lowered design wind speeds, and the WA variation keeps them close to the earlier, higher figures.

The code also reaches the largest hole in most houses. Garage doors and other large access doors in openings up to 3 m high must comply with AS/NZS 4505 in the higher wind regions. The reasoning is the inflation effect described above. A roller door that pulls out of its tracks turns a survivable storm into an internal pressure problem for every room behind it.

All of this governs new work. The code's explanatory note on anchorage contains a sentence that applies just as well to a house built in 1965: each connector must be capable of carrying the uplift force, because the ability of the building to resist the wind is directly related to its weakest link.

In an older house the weak links are well known to anyone who has pulled one apart. Roofing fixed with too few fasteners at the edges. Battens nailed, not strapped, to rafters. Rafters skew-nailed to the top plate. And at the bottom, a frame that simply sits on its stumps under its own weight. A re-roof is the natural time to deal with the top three, because the connections are exposed and the roofer is already there. Ask for the tie-down details in writing, and ask which wind classification they were designed to.

Three practical points follow for owners in the north.

  1. Find the classification on your plans. It is usually on the first sheet or in the engineer's notes. If you are buying, ask for it.
  2. When you extend, the new work is classified for the site as it is now. Cleared bush or a new estate edge may mean a higher class than the original house.
  3. Treat a builder's suggestion to "drop it to the lower class to save money" with suspicion. The WA regulator's audits exist because that saving is real and the consequences are borne by someone else, later.

Questions readers ask

Is a house in Perth or Brisbane built to a cyclone rating?

Not usually. The cyclonic C classifications apply in the cyclonic wind regions shown on the building code's map, which follow the northern coastline. Most suburban sites in the southern capitals fall in non-cyclonic regions and receive an N classification, with the number depending on terrain, hills and shielding.

Who decides the wind classification for my block?

The designer or engineer determines it, using AS 4055 where the house fits within that standard's limits or AS/NZS 1170.2 where it does not, and the building surveyor or certifier checks it. Western Australia's regulator has reported finding errors at that stage, so it is reasonable to ask how the terrain, topography and shielding were assessed.