Condensation and mould in the sealed-up house
We have spent twenty years making houses more airtight and better insulated. The water vapour a household makes still has to go somewhere, and the building code now says where.
The old weatherboard house had a ventilation strategy, though nobody called it one. Air came in around the sash windows, up between the floorboards and through the wall vents with the cast-iron covers, and it left through the chimney and the gaps in the ceiling lining. The house was cold and expensive to heat. It was also hard to grow mould in, because nothing stayed damp for long.
Then we fixed the draughts. We sealed the windows, insulated the ceiling, blocked the fireplace and bought a clothes dryer. The house became warmer, and in a good many cases the south-facing bedroom acquired a grey bloom in the corner above the wardrobe.
Where the water comes from
Condensation is a matter of arithmetic. CSIRO's building technology guide gives the example. A cubic metre of air at 25 degrees can hold at most 23 grams of water. Cool that air to 15 degrees and its capacity falls to 13 grams, so 10 grams must come out as liquid. The temperature at which air can hold no more is its dewpoint, and any surface colder than the dewpoint of the air touching it will get wet.
The federal YourHome guide adds a pair of figures that show how little margin a winter house has. At 20 degrees and 80 per cent relative humidity, the dew point is 17 degrees. A window pane, an uninsulated corner or the back of a wardrobe on an outside wall only needs to be three degrees cooler than the room.
The supply side is larger than most people guess. CSIRO puts an adult's output at about 0.1 litres of water vapour an hour from breathing alone. Hot baths, showers and unvented clothes dryers can produce between 1.5 and 10 litres an hour. Gas, oil and kerosene heaters and stoves that burn without a flue release large quantities of water as a product of combustion, which is the reason an unflued gas heater makes the windows run. YourHome's list is the same in plainer words: breathing, showering, cooking, washing, drying clothes indoors, and burning gas at a cooktop or heater.
The condensation you cannot see
Water on the bathroom mirror is a nuisance. The condensation that damages houses forms out of sight, and CSIRO describes the routes. Where interior linings do not resist vapour, moisture passes into the wall, roof or floor structure and condenses there. Metal roofs are a special case. On a clear night, through what the guide calls radiation cooling, sheet roofing can fall below the temperature of the outside air, and moist air then condenses on the underside of the metal inside the roof space. Anyone who has found the top of their ceiling batts wet under a sound roof has met this.
The guide also notes a pattern by region. Cold, wet winter climates tend to have their problems in the heating season. Hot, humid climates have them in the cooling season, when warm damp air from outside meets surfaces chilled by air conditioning, including the walls beside indoor units.
What the code now requires
Condensation management entered the National Construction Code as its own Part, and the 2022 edition of the Housing Provisions, Part 10.8, sets requirements that are easy to check on a new house or a renovated bathroom.
Exhaust fans have minimum flow rates. An exhaust system in a bathroom or toilet must move at least 25 litres of air a second. In a kitchen or laundry the figure is 40 litres a second.
Exhaust must go outside. Air from a kitchen, a range hood, a bathroom, a toilet or a laundry must discharge directly, or through a shaft or duct, to outdoor air. A fan that blows into the roof space does not comply, and it is delivering shower steam to the coldest surface in the house.
So must the dryer. Where a venting clothes dryer is installed, it must discharge to outdoor air in the same way.
Fans on light switches need a run-on timer. Where a bathroom without sufficient natural ventilation has a fan that does not run continuously, the system must keep operating for 10 minutes after the light switch is turned off. The steam does not leave when you do.
Wall wraps must let vapour out. Where a pliable building membrane, sarking or an insulation layer sits on the outside of the main insulation in an external wall, it must have at least a minimum vapour permeance. The code's explanatory note points out that many foil-faced products have low permeance, and that open-cell insulation such as mineral wool or fibreglass is highly permeable while closed-cell products such as polystyrene are not. Where no membrane is installed, other than in single-skin masonry or concrete walls, the water control layer must be separated from water-sensitive materials by a drained cavity.
These provisions apply to new work. They are also a sound specification for an old house, and the first three cost little.
Fixing a house that already has the problem
Start with the sources, because they are cheaper to change than the building.
- Run the bathroom fan during the shower and afterward, and find out where its duct ends. If it stops in the ceiling, extend it to an eave or roof vent.
- Use the range hood when cooking, and check it is ducted out. Recirculating hoods filter grease and return the steam.
- Dry clothes outside when you can. YourHome lists it among the basic habits, alongside using exhaust ventilation whenever you cook or shower.
- Replace or flue an unflued gas heater.
Then look at the cold surfaces. CSIRO explains winter condensation as the result of insufficiently insulated surfaces falling below the dewpoint of the indoor air, and notes that even a well-insulated building may have heat bridges where warmth escapes and a cold spot forms. Mould in the top corner of an external wall usually marks the place where the ceiling insulation stops short of the wall plate. Mould behind furniture marks still air against a cold wall. Pull the wardrobe forward a hand's width and the patch often stops growing.
YourHome's summary of the design problem is that the balance of ventilation and airtightness, and the choice and installation of insulation, "can reduce the risk of condensation or make it worse". That last clause is aimed at the well-meaning retrofit. Foil sarking added under an old roof, or a wall wrapped in the wrong membrane, can trap moisture that used to escape.
Is it rising damp instead?
A damp patch low on a masonry wall may be condensation, rising damp or both. The heritage guide to salt damp lists condensation on internal surfaces as one of the possibilities to rule out at diagnosis, and warns that mistaking condensation for rising damp is common. CSIRO adds that in older buildings with inadequate or failed damp courses, moisture wicked into the wall can supply water vapour that then condenses elsewhere. If the mark is at skirting height and leaves a white crust, read our piece on rising damp before buying a dehumidifier.
Questions readers ask
Can my bathroom fan vent into the roof space?
Not under the current code for new work. Part 10.8 requires exhaust from a bathroom to discharge directly or via a shaft or duct to outdoor air. In an existing house it is worth ducting the fan out for the same reason the rule exists: steam released into a cold roof space condenses there.
Why is the mould worse since we insulated?
Insulation changes which surfaces are cold. CSIRO attributes winter condensation to surfaces that fall below the dewpoint of indoor air, and gaps or thermal bridges in new insulation concentrate the cold at a few spots. Check that the batts reach the edges of the ceiling, and that moisture sources are being exhausted outside.