Australian houses and the trades that keep them standing

Weatherboard JournalWEATHERBOARD JOURNAL

House types

The Queenslander: an owner's manual

Timber, tin and a great deal of air. The high-set house of the north is a machine for staying cool, and nearly everything that goes wrong with one starts where somebody stopped it breathing.

A highset Queenslander on stumps with a front verandah and central stair
Raised floor, deep verandah, light frame: every part of the form is doing a job. Drawing: Weatherboard Journal.

Stand under a high-set house in Brisbane on a February afternoon and the logic of the whole building is around you. The air is moving. The ground is dry. Above your head are the bearers and joists, every one of them visible, and above those a floor that has shade on all four sides. The people who developed this form had no air conditioning and plenty of hardwood, and they solved a hot, wet climate with geometry.

A Queenslander is a light timber frame, lined on one side, sitting on stumps tall enough to walk under or short enough to trip over, wrapped in verandahs and capped with a steep corrugated roof. Owners inherit the charm and the maintenance schedule together. This is a guide to the second.

Underneath: stumps, clearance and air

The space below the floor is the cooling system, the termite inspection gallery and the first place a restoration should start.

The National Construction Code's subfloor provisions explain why. Ground moisture rising into a subfloor creates a damp environment that encourages timber rot, fungus growth and termite activity, and ventilation is what carries it away. The code sorts the country into three zones by relative humidity and asks for more subfloor ventilation in the more humid ones. Coastal Queensland is not the dry zone.

The classic way to ruin this is to build in underneath. Sheeting between the stumps for a rumpus room, a laundry or storage turns an open undercroft into an enclosed subfloor with a fraction of the airflow. If a previous owner has done it, look at the bottom of the wall framing, the stumps behind the lining and the underside of the floor near the bathroom. If you plan to do it, it is building work that needs approval, and the design has to deal with ventilation and termites at the same time.

Clearance matters for the same reasons. CSIRO's termite guide asks for a crawl space with at least 400 mm of clearance to the underside of the bearers, to lower humidity and make visual inspection easy. On a high-set house that is no difficulty. On a low-set one, decades of garden beds and paths creeping up the perimeter can close it off.

The stumps themselves do move. CSIRO's footing guide notes that in buildings on bearers and joists, isolated piers rise more readily than the footings under the walls when clay swells, which domes the floor, and that in areas with warm, wet summers doming is the underlying tendency. A Queenslander on reactive clay will never be perfectly level and does not need to be. It needs stumps that are sound, plumb and in contact with their bearers, each with an intact ant cap. Our piece on restumping covers that job.

The verandah: balustrades that predate the rules

Verandahs are the reason people buy these houses, and their railings are the reason building inspectors sigh. Original balustrades were built to the height that looked right, which is often lower than a modern one, and decorative panels can have gaps a toddler fits through.

Part 11.3 of the Housing Provisions sets the standard for new barriers. A barrier is required where it is possible to fall 1 m or more from the floor to the surface beneath, which describes most Queenslander verandahs. On a balcony, deck or verandah the barrier must be not less than 1 m high. On a stair flight it may be 865 mm above the nosings. Openings, decorative balustrades included, must not let a 125 mm sphere pass through. Where the fall is more than 4 m, horizontal elements between 150 mm and 760 mm above the floor must not make the barrier climbable.

Existing railings are not automatically unlawful because the code has moved on. But when you replace or substantially alter a balustrade, the new work has to comply, and the conversation with your certifier about matching the old pattern at the new height is best had before the joiner starts. Many owners keep the original profile and add a discreet second rail or infill behind it.

Check the structure while you are there. Verandah posts rot at the base where end grain sits on a wet floor, and the fixing of the rail into the post is the part that matters when somebody leans on it.

Holding the roof on

The steep roof sheds tropical rain and gives the hot air inside somewhere to go. It also presents a large surface to the wind. The code's explanatory text on construction in cyclonic areas sets out what a house needs: an anchorage system in which the roof is connected through the walls to the footings by a chain of connections, bracing against sideways collapse, and continuity between every structural element. It adds that the building's resistance "is directly related to its weakest link".

Old timber houses have several candidates. The single-skin walls that give the interiors their character have little bracing compared with a modern frame. Roof framing was often nailed where it would now be strapped or bolted, and the house may rest on its stumps under gravity alone. None of this means an old house is about to leave. It means that re-roofing, restumping and wall repairs are each a chance to add tie-down at the level you have opened up, and that an engineer's hour is cheap at that moment. North of the non-cyclonic regions, it is not optional thinking. See our piece on wind classifications.

What is in the walls and under the paint

A house that has stood for the better part of a century has been painted, patched and extended by people working to the standards of their own day.

Lead. The federal government's lead paint booklet says paints containing as much as 50 per cent lead were used inside and outside homes built before 1950. Tongue-and-groove walls, fretwork, window sashes and verandah floors have all had decades of it. Dry sanding is the method the booklet rules out by name. Read our guide to repainting weatherboards before stripping anything.

Asbestos. Additions and alterations are where it turns up. Verandahs enclosed as sleep-outs were very often lined with flat asbestos-cement sheet, and CSIRO's list of asbestos products includes cladding pressed to imitate weatherboard or brick, eaves linings and wet area underlay. The original timber house may be clear while the 1960s bathroom at the back is not.

Wiring and plumbing. Old houses collect amateur electrical work. Queensland's Electrical Safety Office is unambiguous that installing a light switch or power point, or swapping a light fitting for a ceiling fan, is work for a licensed electrician. Plumbing, drainage and gas fitting need a QBCC licence at any value.

Hiring for an old house

In Queensland, building work valued over $3,300 needs a QBCC licence and, for residential work, cover under the Queensland Home Warranty Scheme. A contract above that figure must be in writing, and at $20,000 or more it becomes a Level 2 contract with a deposit capped at 5 per cent.

Beyond the paperwork, ask a prospective builder what they did on their last old timber house. The answer you want involves numbering and storing original boards, splicing in matching hardwood, and stopping to phone you when they found something unexpected behind a wall. Old houses reward people who expect surprises and price for them honestly.

Questions readers ask

Can I enclose under my Queenslander?

Often, with approval, but it changes how the house works. The building code's subfloor provisions exist because damp, still air under a timber floor encourages rot, fungus and termites. An enclosure needs designed ventilation, a termite management approach that still allows inspection, and in flood-prone areas a check of what the council permits below the habitable floor.

Do I have to raise my verandah railing to 1 m?

The 1 m minimum in Part 11.3 applies to new barriers. Whether an existing railing must be upgraded depends on what work you are doing and on your certifier's assessment, so ask before you start. If children use the verandah, the 125 mm gap rule is worth meeting whether or not anything compels you to.

Sources

  1. NCC 2022 Housing Provisions, Part 6.2 Subfloor ventilation, Australian Building Codes Board
  2. NCC 2022 Housing Provisions, Part 11.3 Barriers and handrails, Australian Building Codes Board
  3. NCC 2022 Housing Provisions, Part 2.2 Structural provisions, Australian Building Codes Board
  4. Managing Termites, CSIRO Building Technology Resources
  5. Foundation Maintenance and Footing Performance, CSIRO Building Technology Resources
  6. Asbestos in Buildings, CSIRO Building Technology Resources
  7. Lead alert: the six step guide to painting your home, Australian Government
  8. Don't do your own electrical work, Electrical Safety Office (Queensland)
  9. Who must hold a QBCC licence, Queensland Building and Construction Commission
  10. Deposits and progress payments, Queensland Building and Construction Commission